Appliances then hardwired to outlet plate. Induction Hob. My electric Zanussi hob has recently started tripping the mains electric. Clarky94 said: ↑. Ideally you need an electrician who is capable of undertaking kitchen fitting and knows a gas fitter. lee49 New Member. Screwfix Community Forum. now there is a electric hob and electric oven. I was advised when I bought the hob that it would fine to put it on the same circuit as the cooker (max 2. Deals and Offers. 320-320B Vauxhall Bridge Road. Remove the cooker connection plate and replace it with a single socket. sally green Active Member. You may be able to fit 2x 16mm end panels in the gaps if your opening is 632mm. Buy Electric Hobs at Screwfix. MGW Screwfix Select. £239. Accommodates Movement of ±7. Click & Collect. Yes, they would work perfectly well if plugged in on a 13A socket but the circuit would quickly overload when other appliances were plugged in. 95 Inc Vat. Hisense BI64211PB Built-in Single Multifunction pyrolytic Oven - Black. Induction Hob. Just bought a new gas hob (rated at 7. Should the product require repair please contact our repair service to arrange collection and repair. Each of the ovens is 5. . £4. Can I wire L1 into the existing 20A feed into the existing feed that is being used, but wire the L2 into. 0800 324 7818. Bob Rathbone Screwfix Select. Single oven yes. 1 If there is another gas inlet on the other side of the hob, by running the pipe with a curve (not a fitting) from the right of the hob at a high level into the back of the cupboard / space to the left, and fitting the mandatory gas valve in that space. 85 kg. Electric Hobs 5 products Compare Sort Sort Samsung NZ64H37070K_BK 59cm Electric Hob - Black £ 383 Add to basket Smeg SI2951D_BK 90cm Electric Hob - Black £ 1,373. Assembly over oven, figure 2b. Helps to prevent mould and mildew. £4. Its a good bet that the socket will fail after some use. stateit, Jan 11, 2014. Question is cable supplied with hob is 1. Discussion in 'Electricians' Talk' started by Ozwald Cobblepot, Sep 11, 2022. I will follow your advice to get a 13amp max oven and just have the oven and GAS Hob connected. The easy route would be to hardwire the hob in and to fit a single 13A socket for the oven and just plug it in. Product Width. 0800 324 7818. I went round the house turning everything off and finally identified the culprit - my gas hob! I turned it off at the isolator switch above the worktop and then I. Ah ok so it's the same wiring as an electric hob, but slightly more complex is that right? HannahBanana, Sep 13, 2017. 5MM2. HiNeff N50 T26BB59N0 Cast Iron Gas Hob - Stainless Steel. Hello. 1KW/32amp. I don't even get to turn the hob on, as soon as i turn the isolator switch on with the hob connected it trips the RCD. Is is normal practise to wire both appliances into the outlet that is supplied by the 45A DP cooker switch on the wall? I appreciate your time if you can. More precise cooking. Page 1 of 1. LOGIK LCHOBTC23 59 cm Electric Ceramic Hob - Black. Most are under 3 kW (approx rating for a 13A plug) 4 ring hob, probably not; unless it's a 2 ring 'domino hob' pulling less than 3 kW. 3 kw 10 ampI currently have an Electric oven on a cooker circuit with a 32 AMP MCB and a Gas Hob on the Kitchen circuit with a 32 AMP MCB. Lectrician Screwfix Select. leaks. its been a long time since i did 3 phase calculations so need to do some research again. 85 kg. Bazza Screwfix Select. 2 x Ceramic Plates. The distance between the top of the hob and the top of the. 5mm cable, but you need to change some jump connections on the unit itself depending on the power source; But it will not work at full capacity which defeats the. Child Safety Lock Mechanism. Free returns. Most gas supplies I have seen come from below the working height and hence not near the actual hob ring. £72. Sign in / Register. (At the moment we have a seperate gas hob) The old oven and gas hob will be replaced with: - Induction Hob - the rating is 6. LAP 45A 2-Gang DP Cooker Switch & 13A DP Switched Socket Brushed Stainless Steel with Neon with Black Inserts (96499) Huge range of Cooker Switches at Screwfix. Currently in Stock. An induction hob is an individual appliance with a set power rating, no diversity. I purchased an electric built under double oven, the first couple wouldn't fit but now I have one with a slant at the back to allow for the gas pipe on the back of wall. Electric Hob or Induction hob, or even gas? Discussion in 'Electricians' Talk' started by MrM, Nov 25, 2019. We delve into the differences between ceramic, solid plate and. If their is an outlet plate on the wall behind the original cooker position, you can connect to this with the 2 extra cables. - Switch 2: connected to 2x. com. I have a electric hob (input 5500W) which my electrician has connected to the cooker switch using a 6mm T+E cable. So in your case we would have 3. 2 x Plate Sizes. Order Cooke & Lewis CLIND60 Induction Hob Black 68mm x 590mm at Screwfix. com. 3kW) which is usually the norm. Repair Service Action. 0800 324 7818. Shop now. You can simply swap the existing outlet plate for the dual one and wire both appliances off it. Total 40 amp. Cooke & Lewis GASUIT4 Gas Hob Stainless Steel 83mm x 580mm (420FH) (76) compare. 00. Have asked the builder to lay in the 4mm cabling for the oven. An induction hob is an electric hob, just has an increased power rating (normally) Dr Bodgit, Sep 13, 2017. I think the hole is too big so not sure if I have to buy a large gas hob to cover space. Add to basket. Hob Type: Ceramic hob. Nomad24 New Member. 29 Inc Vat. 00. The rail should in theory not encroach into the aperture cut Into the worktop to accommodate the hob. The new electric hob manual states; 220-240v total consumption: 6700w fuse 25a / 16a x 2 cable type: HO5v2v2 - f 3x 2. High quality spare part for select models of New World cookers More information. Suitable for Indoor use. Dr Bodgit Super Member. . Page 2 of 2 < Prev 1 2. One of the rings on our electric ceramic hob turns on as soon as we switch on the mains. Hotpoint TQ1460SNE Electric Induction Hob - Black. To install the new induction hob this needs to be hardwired. Two out of four elements in my electric hob have gave up the ghost. If the whole area is grimy, then use a toothbrush with the WD40 to clean thoroughly around the button shaft and wipe it clean. The question is this. However, he seems to have second throughts. Yes, as pointed out above. FREE next day delivery available, free collection in 1 minute. Old hob specs from data sheet below. The feed from the switch goes by 6mm cable to a unswitched 45A cooker outlet plate in the wall hidden behind the cooker, from which another 6mm cable goes to the actual cooker. New, super sharp blade. Discussion in 'Electricians' Talk' started by mb, Jun 9, 2004. Bazza, Feb 4, 2022. However, the oven will still not fit because of a pipe coming down from the hob itself. This is a metal box that has an oven, sometimes a separate grill and 4 heating rings. White PVC Sheathed Cable. I have searched the internet and not found an answer that is specific to gas hob and electric oven. Please do not return to store. could it be wrong MCB rating, faulty MCB? any advice much appreciated cheers, SamDepends on the type of clips/clamps they send with the hob then. portlanders likes this. Products reviewed by the trade and home improvers. Can't see from the spec but hob may be current limited. While I was pondering my options it occurred to me that as induction hobs don't stay warm for an extended period there's perhaps the possibility to in effect fit the induction hobs 'below' the worktop say 30-40mm and have a 'slow close' hinge (s) at the rear of the workspace with a 'fold down' worktop, that closes say 3-5mm above the. Requires 25mm Back Box. Screwfix customers rate this product 4. Delivered by our approved supplier, Find out more. The cooker switch is on the opposite wall to the hob so I couldn’t wire it there even if I wanted to. £ 6. Scolmore is a brand with a very good reputation, and the link you give has a price for it that none of the wholesalers I have accounts with could. Either switch it off and use matches until it dries out or if you know which knob got wet you could just blow-dry that one until it stops clicking. Sharon151 Member. stateit Screwfix Select. Use either the 6mm cable to connect the 2 items, or use heat resistant 2. Current ceramic hob is: Baumatic B12SS - 230v/400v 3N 50/60Hz 6kW 26. I'm just trying to confirm as to whether I can wire a second appliance - the new electric hob - into the same 32A fused 'socket' as the cooker, I don't need to take. 00. Hendo, Oct 2, 2021. 5kw respectively. Cooker is reactivated by resetting the system once the cause of the alert has been investigated and controlled. One wire in the Left hand terminal looks a bit dodgy. Wouldn't that mean a 50a RCB and probably 10mm2 cable? Moldy1, May 10, 2017. SW1V 1AA. Screwfix Community Forum. There most certainly is regarding gas hobs, unless the sink is stainless steel or vitreous ceramic, it has to be a minimum of 150mm from the edge of the sink. Personally don’t. British General 900 Series 45A 1-Gang DP Cooker Switch White (45659) (23) £7. 07kw). #4. 6KW ( Hotpoint CRM 641 D X Electric Hob) For the cooker he has used 10mm 2 twin and earth coming from the consumer unit (2metres away) on its own mcb to a 45A cooker switch then down to a Cooker control. pj123, May 18, 2014. 1/5. Page 2 of 2 < Prev 1 2. Electrical connection 3. com. Child Safety Lock Mechanism. com. Screwed Faceplate. Supplied in a variety of fuel options, this type of equipment is easy and simple to use and has different configurations available to get the best fit for a design. You need to read it properly: The minimum distance between the supporting surface for the cooking equipment on the hob and the lowest part of the range hood must be not less than 55cm from electric cookers and 70cm from gas or mixed cookers. switch may be used to control the two appliances provided that neither appliance is more than 6 feet. So we divide the 10kw, by 230 volts =43. #5. Cool White. drawer must be 70 mm. If so, spray - ideally with a straw - a small amount on that shaft and press the button repeatedly downwards. Bob Rathbone, May 7, 2019. any help on this would be greatly. Screwfix Community Forum. 5mm, does this mean I use a 2. 6a then 30% of fl remaining 10. The current electric hob surface dimension is 77 x 51 cm with the hole being 75. Have a good ‘un Bazza, Oct 2, 2018 #22. I am now looking for an electric hob but have't got the correct power supply to the kitchen. Pay your way. alex250 New Member. The new items are max 2. Requires 25mm Back Box. Features 4 functions including grilling and plate warming. Hi have recently purchased a neff induction hob,set up so far is 6mm cable running from 32amp mcb to 45amp isolator to 45amp connection terminal. Fuse Rating 16 Amps. jasondo23 New Member. For a electric hob, the minimum space above it is 600mm. Safety Gas Cut-Out. I'm about to replace a few kitchen units and want to replace the electric hob and oven with ones that are rated a little higher. My handyman has seen they are connected to two plug sockets behind the oven/hob which are connected on a separate circuit served by a 6mm wire on 32amp fuse (as mentioned in the electric report). I believe the MCB rating to be 100A, but have attached a picture below for reference. Several options available. You can simply swap the existing outlet plate for the dual one and wire both appliances off it. I’m putting this on a couple of threads in the hope I hit the right one. sinewave, Mar 24, 2007. (of course, make sure your sink and hob cut outs are properly templated out! -seal the cut edges of the worktop before fitting the sink/hob. , Mar 15, 2018. All that said there are practicalities that. Screwfix customers rate this product 4. 49 Inc Vat. £240 for a complete new hob - £220 for just the replacement glass top - if you don't feel competent to replicate how it was connected it's an easy. I think I might be able to explain why the hob has two cables. 69 each. kitchen appliances. metrokitchens, Oct 5, 2016. I too am wanting to do this. Suitable for use on domestic stoves, furnace chimneys, industrial ovens and exhausts. According to Neff, for the hole cut out of the worktop, the minimum front and back distances from hob to back wall and front edge to counter are 50mm (front) and 55 mm. That means the top of the pan supports not the worktop. Worktop 20mm. 4 x Plates. wrighty wrongy Member. 6 x 49. Delivery. Ind spark Screwfix Select. 4mm heat resistant flex, wire neutral to N1 or N2 live to L1 or L2 leave the links in, using the 220 to 240 picture. Screwfix Select. You simply use a standard cooker circuit. Turn off the 32amp MCB to check. £10. Repair Service Contact. 98 Inc Vat. 30 day money back guarantee. No Timer Function. The most practical way IMHO is to install a single socket in an adjacent base unit so you can plug in the hob ignition. 2 x Plate Sizes. Hobs Sort By: Cooke & Lewis CLCER60a Ceramic Hob Black 52mm x 590mm (277GX) (94) compare 4 x Ceramic Plates 2 x Plate Sizes Child / User Safety Control Lock. 5MM2. White PVC Sheathed Cable. Hob: must have a minimum thickness of 30 mm. 49 Inc Vat. 6 So my cooker circuit is not adequate enough. 30 day money back guarantee. robertpstubbs Screwfix Select. Several light coats will give a better finish than a single heavy coat. 9Kw/32amp and hob is at 11. Click & Collect. It's explained in the hob manual. Black PVC Sheathed Cable. kitfit1 Screwfix Select. Discussion in 'Just Talk' started by koolpc, Aug 27, 2022. Looking to run a supply to a new electric hob and 3kw integrated oven. You simply want to find out which fuse is on the Oven circuit and what its rating is (guessing 32A). Lee58 New Member. Ah no. Now we take off the first 10 amps and then use 30% of the remainder so, 33. View all: No Nonsense Spray Paints. In the past we have always had freestanding cookers hardwired into the mains cable coming out of the wall. 5 Radial to a 45A DP Cooker Isolator switch. British General 900 Series 10A 1-Gang 3-Pole Fan Isolator Switch White (69862) (42) compare. with diversity could i get away with feeding both from the cooker circuit ? I am inclined to put in a additional 13 amp supply for the oven but just thought id ask you guys opinions . Product Width. He has backed ou and need to revert to NAPIT for advice. The technical data states, conductors (number & size)3 x 2. Screwed Faceplate. Alternatively you could take a 13A fused spur off the closest socket and connect the hob. 29 Inc Vat. 99% of hobs the cutout is 10mm smaller than the overall size of the hob so a hob with a cut out of 492 (490+2) will actually be at least 510mm deep overall so will cover the existing cutout by 6mm either side. If you must go the FCU route then just go on the Screwfix site and type FCU in the search box. 45. Hi, Cheers for the quick response. #2. Cooke & Lewis GASUIT4 Gas Hob Stainless Steel 83mm x 580mm (420FH) (73) compare. 7 Strands Per Core. (13) £. It's rated at 32 amp, recently got my entire fuse box re-done a few months back due to problems with it and I've no idea if this is supported. 1-800 932 230. High Dielectric Strength. Available with or. 3. I went from gas to induction hob and wouldn't go back. I have seen one oven and hob at 10. At the CU, there is a 30A switch labelled 'cooker' which when flicked down turns off the cooker and the 2 gang socket. You should use the existing cooker circuit for the new oven, to reduce the load on the ring (socket) circuit. most hobs need minimum of 4mm cable and a 32 amp fuse at the consumer unit supplying only the hob. Looking at the oven although its 880 height (including legs) the top is basically the controls with beding that 40mm lower. Currently have a built in electric oven which is hard wired in to the cooker switch & socket, and a gas hob with elec spark which is plugged in to a 2 gang socket in an adjacent cupboard. Most gas hobs do have a 580mm x 490mm cut out size, as do most 600mm ceramic/induction hobs. Great deals on Electric Hobs. 99 Inc Vat. 5KW and I have put it on a 32A breaker, with 6mm cable. £11. From £9. No one on here knows your ability, although I was an electrician I am now retired so electricial work I do is DIY, OK I have test equipment, but if we were to follow what we should do, then there. Order Cooke & Lewis GASUIT4 Gas Hob Stainless Steel 83mm x 580mm at Screwfix. £ 3. Please do not return to store. however, the oven I’ve chose is a single integrated with a 13a plug on it. I am exploring the option of swapping my neff gas hob for an electric induction one. 0800 324 7818. That will dictate how much power can be drawn from it and hence whether you can connect both appliances to the one circuit. The strip has to go on the edge of the appliance, then trim the excess off, very gently, as not to scratch the hob or work surface. K Piezoelectric Gas Lighter. My electric Zanussi hob has recently started tripping the mains electric. Cooke & Lewis CLCER30A 29cm Ceramic Hob - Black. The oven is just plug in but the hob needs hard wiring. I do not know of any electric hob that will utilise a 13amp plug . Timer. 590 mm. sinewave Screwfix Select. 1. Write a review. Both the hob and the oven can pull their maximum current of 2 x 13 amp (26amp). Having ploughed through loads of specification on AO. From the photos, it’s pretty clear that the glass cooktop has detached from the frame that holds it into the recess. I hope this the right thread. Buy a bundle. 9% APR representative (variable)* +2 more offers. I have bought a new kitchen. I have an existing single one electric oven & standard electric hob, both hardwired into a flush dual outlet plate (one gang). FREE next day delivery available, free collection in 1 minute. 68 per month*. Home Forums > Screwfix Community Forum > Electricians' Talk > Electric Oven and Electric Hob Discussion in ' Electricians' Talk ' started by RedRick , Nov 8, 2004 . Don't be tempted to use masses a small bead. Now I'm not so sure. Repair Service Contact. Dimensions: (H)5cm x (W)30cm x (D)52cm. Repair Service Contact. FREE next day delivery available, free collection in 1 minute. Water & Flame-Resistant. I do not have the luxury of being able to run a new cable from the CU, not without a lot of disruption to many rooms. Mike83 Screwfix Select. If you come up with a figure of much more than 32 amps don't panic, it could still be ok if diversity is taken into account. 2m flexi with 5 dif colour cables in side,black red,blue grey &yello/green , earth So looking at witing diagram Blue+grey to neutral,black ,brown to live. 5 hr flex is fine if its a gas one 1. com. I want to get a new hob. com it seems the vast majority of the cheaper single ovens only take 13amps, some even come with a 13 amp socket. Most sockets feeding things like dishwashers and washing machines are mounted inside an adjacent cupboad. Most CERAMIC hobs are rated above 3kW and also require a 32A radial circuit. The existing hob is connected to its own plug socket. My neighbour has asked a qualified gas engineer to provide a gas connection point in her kitchen for a new gas hob. Buy any 10+ Save 10% - View Offer. 5a. Check the kW rating of the hob, in most cases a 6. Allow to dry between coats. Permanent Adhesive. Hans_25 Screwfix Select. 49 Inc Vat. Convenience: These hobs are designed for swift and trouble-free setup, making them. The fridge was pretty tight to the bottom of the kitchen top and the bottom of the hob was pretty much flush with the bottom kitchen top aswell. FREE next day delivery available, free collection in 1 minute. Samsung NZ84F7NC6AB_BK 80cm Electric Hob - Black (2) £ 818. I have and electric cooker hardwired into a cooker point that is within 2m of the cooker - i also want to put and electric induction hob on the other side of the kitchen, i will but putting in a separate feed does this also have to have a cooker switch and does it need to be visible? Neither a cooker nor a hob need isolation. Buy 13 A Electric Plugs at Screwfix. The designer of the circuit has determined that the 32 amp MCB is the suitable OPD for the circuit. You can effortlessly plug it into a standard 13 amp electrical socket without the need for specialised wiring or professional help. UK call centre ready for your call. Requires 25mm Back Box. It doesn't trip every time I switch it on. 1 x Ø 380 mmx230 mm, 3. Screwed Faceplate. So in your case we would have 3. Bosch PCP6A6B90 58cm Gas Hob - Black. Screwfix Community Forum. Order Cooke & Lewis GASUIT4 Gas Hob Stainless Steel 83mm x 580mm at Screwfix. Instant heat and easy to manipulate to the required temperature. Screwfix Community Forum. Product Width. Repair Service Action. So I think I can just plug the oven into the ring main and use the 32amp feed for the hob. We currently have a built in electric oven, this is plugged in behind the. Instructions say hob must be connected to a fused spur outlet with 3A fuse and oven must be connected to a fused spur outlet with 13A fuse (using 1mm cable). Twin Grill. Discussion in ' Electricians' Talk ' started by Curiouscat, Jan 26, 2009 . com. 5 thanks in advanceBush RL60SPH Electric Solid Plate Hob - Stainless Steel. The hob is sat right on top of the ovens and there is a small gap between the hob and the worktop at the front (see attached pics) Now its all. Offer - 20% off this when you spend £1500+ on kitchen worktops, cabinets and doors. 4KW load, ideally I'd like to be able to have the 20Amp option to get the most out of it. The installation instructions for the induction hob state that it requires direct connection to the mains and requires a 32A. Delivery 7 days a week Pay your way. 5kW blasting away in all. 5cm. I I guess I put both lives in the live and both neutral in the neutral the. Add for Delivery. The pan base heats up. I'm about to replace a few kitchen units and want to replace the electric hob and oven with ones that are rated a little higher. View all: Unika Worktop Fittings. Just as I thought, ie the repair not being cost-effective. The Sigma3 countertop depth is the standard 600 mm but the splashback thickness (approx 15 mm) clearly reduces the useable depth to less than the minimum 600 mm required by Neff. You could fit a plug to the hob with a 13A fuse in it. A user asks how easy it is to change an electric hob for another one at home. I would like to have them replaced by by both electric hob and electric oven. £13. The hob comes with a 13amp plug so all that is needed is for her to plug this into an adjacent wall socket. 5mm or equiv cable length max 2m The hob has connectors for a cable but no supplied cable or plug The oven manual states 220-240v cable type: HO5VV-F 3X 1.